Item #862682

Blue Sea Systems ML-ACR Automatic Charging Relay

$291.80 - $304.42
                  Want an email once available?

                  Image of : Blue Sea Systems ML-ACR Automatic Charging Relay Blue Sea Systems ML-ACR Automatic Charging Relay Item # 862682

                  Description

                  500A magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.

                  Features:

                  • Automatically manages the charging of two large battery banks
                  • Allows paralleling of battery banks for emergency starting
                  • 500 Ampere continuous rating to support high-output alternators
                  • Magnetic Latch (ML)—ACR draws very low current (<40mA to monitor terminal voltage) in the "ON" or "OFF" states, and draws moderate current for very short time when changing state
                  • Dual sensing—senses charge on both battery banks
                  • Start Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics
                  • Engine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output
                  • Senses charging on two battery banks
                  • LED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation
                  • 3/8"-16 tin-plated copper studs for maximum conductivity and corrosion resistance
                  • 7/8" (22mm) stud length accepts multiple cable terminals
                  • Silver alloy contacts provide high reliability for switching live loads
                  • Label recesses for circuit identification

                  Specifications:

                  • Control Circuit Connection : Tinned Wire or Deutsch DTM / Amphenol ATM
                  • Nominal Voltage: 12 or 24V DC
                  • Manual Control : No
                  • Engine Isolation : Yes
                  • Mounting: #10
                  • Start Assist : Yes
                  • Start Isolation : Yes
                  • Amperage Operating Current: 13mA
                  • Amperage Operating Current when changing state: <7.0A
                  • Terminal Stud Torque: 140 in-lb (15.82 Nm)
                  • Continuous Rating : 500A
                  • Intermittent Rating : 700A (5 min)
                  • Cranking Rating 30 sec : 1450A DC
                  • Cable Size to Meet Ratings: 4/0 AWG x 2
                  • Live Current Switching: 300A @ 12V DC
                  • Switching Cycles: 100000
                  • Terminal Ring Diameter Clearance: 1.18" (29.97 mm)
                  • Terminal Stud Length: 1.50" (38.1 mm)
                  • Terminal Stud Size: 3/8" - 16 (M10)

                  Data Sheet

                  Part Numbers for Blue Sea Systems ML-ACR Automatic Charging Relay

                  Reviews

                  • bvseo_sdk, p_sdk, 3.2.1
                  • CLOUD, getReviews, 21.87ms
                  • REVIEWS, PRODUCT
                  • bvseo-msg: HTTP status code of 404 was returned;

                  Questions

                  • bvseo_sdk, p_sdk, 3.2.1
                  • CLOUD, getContent, 33.57ms
                  • QUESTIONS, PRODUCT
                  • bvseo-msg: HTTP status code of 404 was returned;